Precautions for use when extracting and concentrating units

1. After the heating chamber has drained the liquid, because the shell temperature is high, in order to prevent the heating tube from drying, immediately drain the heating tube from the valve F55.

2. The whole set should have an electrostatic grounding device to prevent accidents during alcohol extraction.

3. The condensed water in each heating chamber is discharged by a heat-type steam trap. When the heating is started, the steam trap is not drained due to the low temperature of the condensed water. At this time, the bypass valve can be opened to condense the water. When the bypass valve has steam exhausted, close the valve and the steam trap can work normally.

4. When the water ring vacuum pump is working, it should be cooled by water. For the convenience of operation, the pneumatic valve C10 should be opened when the vacuum pump is started. At the same time, the valve of the water ring vacuum pump is not equipped with a valve.

5. Manually control the slag door: After determining the normal connection of the air pipe at each position, turn the 1# hand rotation valve to the door closing position → 2# hand rotation valve to the locking position → 3# hand rotation valve to the loading position; After the work is completed, the 3# hand rotation valve is turned to the unloading position → 2# hand rotation valve is turned to the unlock position → 1# hand rotation valve is turned to the opening position.

Normal operation. Non-professionals must not change their layout and will be in danger!

6. Electrical control slag door: The wiring of the electronic control part of the slag door should be carried out according to the wire number on the wire and the indication method in the electric control box.

(1) Check if the position is connected correctly. After confirming, pass the compressed air test run.

(2) Closing energization → Press the closing button to the locking position → press the locking button to the locking position → press the infeed button to the locking position → to work.

(3) After the work is completed → Exit the sales and self-locking → Unloading → Exit the lock and self-lock → Unlock → Exit the door to lock the door → Open the door.

Closing, locking, and invoicing must be pressed into the lock position to prevent unnecessary loss and damage caused by sudden power failure! In the working state, if there is a sudden power failure, there is no need to operate, and it is still in a locked state. After the work is completed, during the work, the hand rotation valve must not be turned without any reason, and it will be dangerous! ! !

Manual Wheelchair

It is an important mobile tool for the home rehabilitation of the wounded, sick, and disabled, turnover transportation, medical treatment, and outing activities. The Wheelchair not only meets the mobility of the physically disabled and the disabled, but more importantly, it is convenient for the family to move and take care of the sick. Allow patients to use wheelchairs to exercise and participate in social activities.