Infectious hematopoietic organ necrosis virus (IHNV) nucleic acid detection kit (one-tube constant temperature fluorescence method)
product manual
The animal disease detection series is based on a unique thermostated fluorescence detection technology that can amplify specific nucleic acid fragments of viruses in samples such as food and animal tissues, and judge the results by real-time amplification curves. This product is used for the detection of infectious hematopoietic necrosis virus (IHNV) with a detection limit of 10 3 copies/μl genomic RNA .
â—† Product composition ( 96 test)
032021L III | |
Reagent | content |
A-IHNV-I | 22μL × 96 tubes |
BI | 90 μL × 2 |
RI | 12 μL × 2 |
NG-I | 50 μL × 3 |
PG-IHNV-I | 50 μL × 2 |
â—† Applicable instruments
Dhelix-C, ESE Tube Scanner, Genie II, Deaou-308C and other constant temperature fluorescence detectors, ABI 7500, LightCycler480, CFX 96 and other fluorescent PCR instruments.
â—† Self-supplied supplies and instruments
1 Sterilize 1.5mL or 2.0mL centrifuge tube; 2 ice box; 3 pipette (0.1-2.5μL, 0.5-10μL, 10-100μL, 100-1000μL) and matching sterilization tips; 4 centrifuge; 5 vortex Rotary mixer; 6 metal bath
â—† Notes
1. This reagent has high detection sensitivity. In order to prevent pollution, the experiment is to be partitioned.
1) First zone: sample preparation zone.
2) The second zone: the template addition zone.
3) Zone 3: Amplification and product analysis zone.
★ It is best to physically isolate the partitions to avoid pollution caused by human factors.
2. Work clothes and latex gloves are worn during the experiment, and tools are used independently in different areas. Gloves and lab coats need to be replaced.
3. Strictly follow the operation steps, reagent preparation and sample loading steps, please operate in strict accordance with the instructions on the ice box.
4. The components in the reaction solution are sensitive to light and should be stored away from light . The reagent should be completely thawed before use, but repeated freezing and thawing should be avoided. It is recommended to centrifuge for 30 seconds before use.
5. After the reaction is completed, the expansion tube should be placed in a sealed bag and discarded. On the same day, the lid is opened and the aerosol is easily contaminated. It is forbidden to open the lid.
6. Do not mix different batches of reagents used within the validity period.
â—† Sample processing
The prepared samples are kept for use according to the "GB/T 15805.2-2008 Fish Quarantine Method Part 2: Infectious Hematopoietic Organ Necrosis Virus (IHNV)" or other standard processing samples.
For detailed steps, please follow the standard operation or check the food safety software.
â—† Experimental operation
1. Template preparation (sample preparation area)
It is recommended to use the aquatic animal virus genomic DNA/RNA extraction kit series. The specific process is detailed in the product manual.
2. Add a template (template add area, placed in the ice box)
The required test number of the PCR tube containing the reaction solution was taken out, the reagent was completely thawed, and after thawing, the tube cover was opened and 0.8 μL of BI and 0.2 μL of RI were added to the bottom of each tube, and the tube lid was centrifuged for 1 min. Open the tube cover and add 2 μL of template along each tube wall in the order of NG-I, sample template to be tested, and PG-IHNV-I. After the PCR tube cover was capped, it was centrifuged for 3 min, and the PCR amplification reaction was immediately performed.
3. Amplification reaction (amplification and product analysis area)
1 The constant temperature instrument was reacted at 63 ° C for 30 min.
2 If a real-time PCR instrument is used, the fluorescent group is selected as FAM, the quenching group is selected as None, 63 ° C for 15 s, 63 ° C for 45 s as a cycle, and the fluorescence signal is collected at 63 ° C for 45 s, 30 cycles.
For other instruments, please refer to the instrument manual for setting.
â—† Result judgment
1 The instrument automatically determines the result. If “positive†is displayed, the sample contains infectious hematopoietic necrosis virus (IHNV); if “negative†is displayed, the sample does not contain infectious hematopoietic necrosis virus (IHNV) or The content is below the detection limit. For example, if the curve rises between 20min and 30min and the automatic interpretation result is negative, it may be due to the low sample content, it is recommended to enrich the sample or extend the reaction time to 45min for review.
2 On the fluorescence quantitative PCR machine, the results were determined based on the presence or absence of the "S" type amplification curve. If there is an "S" type amplification curve, the sample contains infectious hematopoietic necrosis virus (IHNV); if there is no "S" type amplification curve, the sample does not contain infectious hematopoietic necrosis virus (IHNV) Or the content is below the detection limit.
- The result of the NG reaction tube showed "negative", and the result of the PG reaction tube showed "positive". The test result was valid, otherwise it was invalid. If the duplicate test results are still invalid, please contact technical support.
A digital Hotel Safe is a secure storage device found in hotel rooms that uses electronic technology to provide guests with a secure place to store their valuables. Unlike traditional hotel safes, which typically use a physical key or combination lock, digital hotel safes use a digital keypad or touchscreen interface to allow guests to set their own unique passcode.
Digital hotel safes offer several advantages over traditional safes. Firstly, they are more convenient to use, as guests can easily set and change their own passcodes without needing assistance from hotel staff. Secondly, they provide a higher level of security, as the passcodes are typically encrypted and more difficult to guess or crack compared to physical keys or combinations.
In addition to the passcode entry, digital hotel safes may also offer additional security features such as an audit trail, which records the date and time of each access attempt, as well as a tamper-proof design to prevent unauthorized access.
Digital hotel safes come in various sizes and designs to accommodate different types of valuables, such as laptops, jewelry, passports, and cash. They are typically mounted securely to a wall or inside a cabinet to prevent theft or unauthorized removal.
Overall, digital hotel safes provide guests with a convenient and secure way to store their valuables during their stay, giving them peace of mind knowing that their belongings are protected.
Custom Deposit Hotel Safe,Steel Digital Hotel Safe,Electronic Password Safebox
Hebei Hupai Aodi Cabinet Industry Co.,Ltd. , https://www.hupaiaodi.com